Tianjin
Tianjin cabinet type perfluorohexanone nozzle selection table
In recent years, fire accidents have occurred frequently, posing a huge threat to people's lives and property. Therefore, the research and development of fire extinguishing technology and equipment has become particularly important. As a new type of fire extinguishing equipment, Tianjin cabinet-type perfluorohexanone fire extinguishing nozzles have attracted widespread attention in the field of fire prevention due to their excellent performance and efficient fire extinguishing capabilities. Lanzhong can provide customized services for cabinet-type perfluorohexanone fire extinguishing nozzles according to customer needs to meet the application needs of different scenarios.
![]()
1. Tianjin cabinet type perfluorohexanone nozzle selection
The application scenarios of Tianjin cabinet-type perfluorohexanone nozzles are different, so the specifications and sizes of the nozzles are different, and the model is composed of the main specifications and parameters of the nozzle. Different models of cabinet-type perfluorohexanone nozzles can meet the use of different scenarios. The following is the general selection table of Tianjin cabinet-type perfluorohexanone nozzles:
1. QPT120/4.2, flow coefficient k=120, working pressure is 4.2MPa, interface thread size is Rp1 1/4, commonly used materials are 6061/HPb59/304
2. QPT140/4.2, flow coefficient k=140, working pressure is 4.2MPa, interface thread size is Rp1 1/4, commonly used materials are 6061/HPb59/304
3. QPT160/4.2, flow coefficient k=160, working pressure is 4.2MPa, interface thread size is Rp1 1/2, commonly used materials are 6061/HPb59/304
4. QPT180/4.2, flow coefficient k=180, working pressure is 4.2MPa, interface thread size is Rp1 1/2, commonly used materials are 6061/HPb59/304
5. QPT200/4.2, flow coefficient k=200, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304
6. QPT220/4.2, flow coefficient k=220, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304
7. QPT240/4.2, flow coefficient k=24, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304
2. Parameters of Tianjin cabinet type perfluorohexanone nozzle
The parameters of cabinet-type perfluorohexanone nozzles are crucial to the normal operation and fire-extinguishing effect of the fire protection system. Correct selection of the nozzle model, size, working pressure, spray angle, spray mode and material suitable for specific application scenarios can confirm that the nozzle can respond quickly when a fire occurs and effectively extinguish the fire, ensuring the safety of people and property. Therefore, when designing and installing a fire protection system, the parameters of cabinet-type perfluorohexanone nozzles should be carefully considered and configured to confirm the stability and effectiveness of the system.
The following are the main parameters of Tianjin cabinet-type perfluorohexanone nozzle:
1. Nozzle model: The model of cabinet-type perfluorohexanone nozzle is usually specified by the manufacturer and is used to identify and distinguish different types of nozzles. Different types of sprinkler heads may have different spray characteristics and fire extinguishing effects, so it is important to correctly select the model suitable for a specific application scenario.
2. Nozzle size: The size of the cabinet-type perfluorohexanone nozzle is usually used to describe its spray range and liquid flow rate. Sizes are generally in inches, and common sizes include 1/2 inch, 3/4 inch, etc. As needed, the appropriate nozzle size can be selected to meet the fire extinguishing agent requirements of the fire protection system.
3. Working pressure of nozzle: The working pressure of cabinet-type perfluorohexanone nozzle refers to the pressure range required under normal operating conditions. The setting of the working pressure should comply with the design requirements of the fire protection system, and confirm that the sprinkler head can spray fire extinguishing agent normally and effectively extinguish the fire.
4. Spray angle of the nozzle: The spray angle of the cabinet-type perfluorohexanone nozzle determines its spray range and coverage area. Common spray angles include 60 degrees, 90 degrees, etc. You can choose the appropriate angle according to your needs to ensure that the fire area is covered in multiple aspects.
5. Spray mode of nozzle: The spray mode of cabinet-type perfluorohexanone nozzle can be divided into several different types such as spray, jet and direct flush. Different spray patterns are suitable for different fire types and application scenarios. Choosing the right spray pattern can improve fire extinguishing effectiveness and safety.
6. Nozzle material: The material of cabinet-type perfluorohexanone nozzle is crucial to its performance and durability. Common nozzle materials include stainless steel, brass, etc. Appropriate material selection can ensure that the nozzle will not be corroded and damaged during long-term use and maintain stable working performance.
![]()
3. Characteristics of Tianjin cabinet-type perfluorohexanone nozzles
Tianjin cabinet-type perfluorohexanone fire extinguishing nozzle is a fire extinguishing device based on perfluorohexanone fire extinguishing agent. Perfluorohexanone is an environmentally friendly, non-toxic, non-conductive chemical with good fire-extinguishing properties. Compared with traditional fire extinguishing agents, perfluorohexanone has higher fire extinguishing efficiency and lower toxicity, which can better protect personnel safety during fire extinguishing.
The nozzle adopts cabinet design for easy installation and maintenance. It has a compact structure and high stability. It can start quickly when a fire occurs and release an appropriate amount of perfluorohexanone fire extinguishing agent in a short time. The spray angle and range of the nozzle can be adjusted as needed to ensure that the sprayed fire extinguishing agent covers a larger area and effectively controls the spread of the fire.
In addition, Tianjin cabinet-type perfluorohexanone fire extinguishing nozzles also have intelligent features. Through linkage with the fire alarm system, automatic monitoring and activation can be achieved to improve the response speed of fire extinguishing. At the same time, the working status and fire extinguishing effect of the sprinkler heads can also be monitored and adjusted in real time through the remote monitoring system, providing a more convenient and stable management method.
4. Application of Tianjin cabinet-type perfluorohexanone nozzle
Tianjin cabinet-type perfluorohexanone fire extinguishing nozzles are widely used in various buildings and places, such as commercial centers, factories, warehouses, libraries, etc. When a fire occurs, it can respond quickly and extinguish the fire quickly, effectively reducing the losses caused by the fire. At the same time, since the perfluorohexanone fire extinguishing agent will not cause secondary pollution, it will not have any negative impact on the environment after being sprayed by the nozzle.
In summary, Tianjin cabinet-type perfluorohexanone fire extinguishing nozzles, as a new type of fire extinguishing equipment, have the advantages of safety and stability, high efficiency in fire extinguishing, environmental protection and energy saving, etc., and provide important protection for our lives and property. In the future, we have reason to believe that with the continuous advancement of science and technology, this advanced fire extinguishing technology will play a greater role in various fields and create a safer environment for mankind.
Anhui Lanzhong Mechanical and Electrical Equipment Co., Ltd.
WhatsApp: +86-138-6598-5643
![]()
Contact person: Alex Wang
Email: alexwang@watermist.com.cn
Address: Room 101-Room 401, Building B8, Gongtou Lingang New Industrial Park, No.21 Science Avenue, Shou County, Huainan city, Anhui Province, China